    How to Maintain Box Atmosphere Furnace
    A. According to the excellent thermal technical requirements, regularly check whether the connection of electric furnace and controller is good or not, whether the indicator pointer is stuck or not when moving, and check the error increase caused by magnet steel, demagnetization, wire expanding, elastomer fatigue and balance damage with potentiometer.
    B. Box-type atmosphere furnace and controller work in places where the relative temperature does not exceed 85 and there is no conductive dust, explosive gas or corrosive gas. When metal materials such as grease need to be heated, a large number of volatile gases will affect and corrode the surface of electrothermal components, which will destroy and shorten their life.
    C. The box type atmosphere furnace controller should be limited to use in the ambient temperature range - 10-75 C.
    D. The thermocouple should not be pulled out suddenly at high temperature in order to prevent the jacket from bursting.
    E. Keep the furnace clean regularly and remove oxides and other things in time.